HomeOverhead Quadruplex XLPE Insulated ABC Cable Four Core Aerial Bundled Cable 0.6kV / 1kV for Overhead Power Lines
Customer satisfaction products , good service !

—— Mr. Alcioni possamai

we are very impressed with the quality of the belts you produced.

—— Mr.Mike

your products are very popular in my markets.

—— Mr. jone

I'm Online Chat Now

Four Core Aerial Bundled Cable 0.6kV / 1kV for Overhead Power Lines

Large Image : Four Core Aerial Bundled Cable 0.6kV / 1kV for Overhead Power Lines

Product Details:

Place of Origin:Henan.China(mainland)
Brand Name:JYTOP or OEM ODM
Model Number:16mm,25mm,35mm,50mm,70mm
Type:Stranded
Conductor Material:Aluminium
Insulation Material:XLPE
Jacket Material:None
Standard:IEC,ASTM,BS,DIN,AS
Certification:CE,ISO9001

Payment & Shipping Terms:

MOQ:1000meters
Payment Terms:T/T, L/C
Delivery Time:Within 15-30 working days
Port:Qingdao, Shanghai, Ningbo
Packaging Details:Coil, Wooden drum, Steel wooden drum,etc…
Detailed Product Description
Standard: BS Standard Conductor Type: RM
Application: Overhead Power Transmission Lines Performance: UV-resistant
Operating Temp.: 90℃ Sample: Available
Drum Length: 1000 Meters Or As Per Request


Four Core Aerial Bundled Cable 0.6/1kV for Overhead Power Lines

 

Aerial bundled cables (also aerial bundled conductors or simply ABC) are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps. This variation of overhead power lines utilizes the same principles as bundled conductors, except that they are closer together to the point of touching but each conductor is surrounded by an insulating layer (except for the neutral line).

 

Design.

1 Aluminium conductor with increased breaking load, round stranded compressed (RM)
2 Core insulation (XPLE black, UV-resistant, not flame retardant); 2 up to 4 cores of equal cross section are stranded together in left-hand lay, additionally 1 or 2 cores of reduced cross section can be co-stranded
Application

Can be used for fixed installation as overhead power lines up to 1.000 V incl.
Not suitable for direct burial.
This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140 It is not flame retardant. But this could be if requested change to a flame retardant cable

Specification

(1). BS Standard ABC Cable

(2). CCC,ISO9001,ISO14001, best quality control.

(3). More than 20 years Proffessional experience, best service.

(4). We are a factory manufacturing ,Best production capability,best Price.

(5). 100% QC inspection before shippment.

Introduction

ABC Cable are overhead power lines using several insulated phase conductors bundled tightly together,

usually with a bare neutral conductor. They can improves safety and reliance of electrified wire netting.

Standard

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.

2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.

3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).

4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.

5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

Applications:

TO supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting.

For service at 600 volt or lower at a conductor temperature of 75 maximum.

Schedule of technical particulars

Phase conductor                  
Nominal cross-sectional area mm² 25 35 50 70 95 120 150 185
Number of cores   3 3 3 3 3 3 3 3
Minimum number of wires   6 6 6 12 15 15 30 30
Nominal insulation thickness mm 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0
Diameter of insulated core mm 8.5 9.5 11.2 13.0 15.1 16.6 18.4 20.6
Max. DC resistance at 20℃ ohm/km 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Current rating at still wind, ambient A 84 104 129 167 209 246 283 332
temperature=30℃
Conductor temperature=75℃                  
Messenger conductor                  
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires   6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Calculated breaking load kN 6.4 6.4 8.9 12.1 18.0 18.0 24.2 30.8
Street lighting conductor                  
Nominal cross-sectional area mm² 25 25 35 50 70 70 95 120
Minimum number of wires   6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20℃ ohm/km 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Completed cable                  
Approx. overall diameter mm 23.2 25.6 30.0 34.9 40.6 44.1 49.2 54.9
Approx. weight of cable kg/km 470 560 740 980 1330 1580 1940 2410
Packing length m/drum 1000 1000 1000 1000 500 500 500 500
 

 